Low temperature thermal resistance for a new design of silver sinter heat exchanger
Low temperature thermal resistance for a new design of silver sinter heat exchanger
We have developed a novel procedure for constructing high surface area silver sinter heat exchangers. Our recipe incorporates nylon fibers having a diameter of ∼50 μm and thin wires of bulk silver in the heat exchanger. In order to increase the thermal conductance of liquid helium within the heat exchanger, …