Calibration of the IXPE Focal Plane X-Ray Polarimeters to Polarized Radiation

Type: Article

Publication Date: 2022-08-18

Citations: 16

DOI: https://doi.org/10.3847/1538-3881/ac7719

Abstract

IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units (DUs) at INAF-IAPS, in Italy, where a dedicated facility was set-up at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

Locations

  • The Astronomical Journal - View - PDF
  • arXiv (Cornell University) - View - PDF
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) - View
  • DataCite API - View

Similar Works

Action Title Year Authors
+ PDF Chat Calibration of the IXPE instrument 2018 Carlo Lefevre
Raffaele Piazzolla
Alfredo Morbidini
Fabrizio Amici
Primo AttinĂ 
Mauro Centrone
E. Del Monte
Sergio Di Cosimo
Giuseppe Di Persio
Y. Evangelista
+ The IXPE instrument calibration equipment 2021 Fabio Muleri
Raffaele Piazzolla
Alessandro Di Marco
Sergio Fabiani
Fabio La Monaca
Carlo Lefevre
Alfredo Morbidini
John Rankin
P. Soffitta
Antonino Tobia
+ An algorithm to calibrate and correct the response to unpolarized radiation of the X-ray polarimeter on board IXPE 2021 John Rankin
Fabio Muleri
Allyn F. Tennant
Matteo Bachetti
E. Costa
Alessandro Di Marco
Sergio Fabiani
Fabio La Monaca
P. Soffitta
Antonino Tobia
+ An algorithm to calibrate and correct the response to unpolarized radiation of the X-ray polarimeter on board IXPE 2021 John Rankin
Fabio Muleri
Allyn F. Tennant
Matteo Bachetti
E. Costa
Alessandro Di Marco
Sergio Fabiani
Fabio La Monaca
P. Soffitta
Antonino Tobia
+ An Algorithm to Calibrate and Correct the Response to Unpolarized Radiation of the X-Ray Polarimeter Onboard IXPE 2022 John Rankin
Fabio Muleri
Allyn F. Tennant
Matteo Bachetti
E. Costa
Alessandro Di Marco
Sergio Fabiani
Fabio La Monaca
P. Soffitta
Antonino Tobia
+ PDF Chat THE IMAGING PROPERTIES OF THE GAS PIXEL DETECTOR AS A FOCAL PLANE POLARIMETER 2014 Sergio Fabiani
E. Costa
E. Del Monte
Fabio Muleri
P. Soffitta
Alda Rubini
R. Bellazzini
A. Brez
Luca de Ruvo
M. Minuti
+ PDF Chat Handling the Background in IXPE Polarimetric Data 2023 Alessandro Di Marco
P. Soffitta
E. Costa
Riccardo Ferrazzoli
Fabio La Monaca
John Rankin
Ajay Ratheesh
Fei Xie
L. Baldini
E. Del Monte
+ PDF Chat Equalizing the Pixel Response of the Imaging Photoelectric Polarimeter Onboard the IXPE Mission 2023 John Rankin
Fabio Muleri
Alessandro Di Marco
Sergio Fabiani
Fabio La Monaca
P. Soffitta
Matteo Bachetti
L. Baldini
E. Costa
Niccolò Di Lalla
+ The Instrument of the Imaging X-ray Polarimetry Explorer 2021 P. Soffitta
L. Baldini
R. Bellazzini
E. Costa
L. Latronico
Fabio Muleri
E. Del Monte
Sergio Fabiani
M. Minuti
Michele Pinchera
+ The Instrument of the Imaging X-Ray Polarimetry Explorer 2021 P. Soffitta
L. Baldini
R. Bellazzini
E. Costa
L. Latronico
Fabio Muleri
E. Del Monte
Sergio Fabiani
M. Minuti
Michele Pinchera
+ Equalizing the Pixel Response of the Imaging Photoelectric Polarimeter On-Board the IXPE Mission 2023 John Rankin
Fabio Muleri
Alessandro Di Marco
Sergio Fabiani
Fabio La Monaca
P. Soffitta
Matteo Bachetti
L. Baldini
E. Costa
Niccolò Di Lalla
+ PDF Chat Analysis of the Data from Photoelectric Gas Polarimeters 2022 Fabio Muleri
+ Analysis of the data from photoelectric gas polarimeters 2022 Fabio Muleri
+ PDF Chat The gas pixel detector as an x-ray photoelectric polarimeter with a large field of view 2008 Fabio Muleri
P. Soffitta
R. Bellazzini
A. Brez
E. Costa
Sergio Fabiani
M. Frutti
M. Minuti
Maria Barbara Negri
Michele Pinchera
+ Angular Resolution of a Photoelectric Polarimeter in the Focus of an Optical System 2009 F. Lazzarotto
Sergio Fabiani
E. Costa
Fabio Muleri
P. Soffitta
Sergio Di Cosimo
Giuseppe Di Persio
A. Rubini
R. Bellazzini
A. Brez
+ Handling Background in IXPE polarimetric data 2023 Alessandro Di Marco
P. Soffitta
E. Costa
Riccardo Ferrazzoli
Fabio La Monaca
John Rankin
Ajay Ratheesh
Fei Xie
L. Baldini
E. Del Monte
+ Design, construction, and test of the Gas Pixel Detectors for the IXPE mission 2021 L. Baldini
M. Barbanera
R. Bellazzini
R. Bonino
Fabio Borotto
A. Brez
Ciro Caporale
Claudia Cardelli
Simone Castellano
M. Ceccanti
+ Polarisation Leakage due to Errors in Track Reconstruction in Gas Pixel Detectors 2023 N. Bucciantini
N. Di Lalla
Roger W. Romani
S. Silvestri
M. Negro
L. Baldini
A. F. Tennant
A. Manfreda
+ PDF Chat Polarisation leakage due to errors in track reconstruction in gas pixel detectors 2023 N. Bucciantini
Niccolò Di Lalla
Roger W. Romani
Stefano Silvestri
Michela Negro
L. Baldini
Allyn F. Tennant
Alberto Manfreda
+ PDF Chat Polarization properties of X-ray tubes used for Imaging X-ray Polarimetry Explorer calibration 2023 Ajay Ratheesh
John Rankin
E. Costa
E. Del Monte
Alessandro Di Marco
Sergio Fabiani
Fabio La Monaca
Fabio Muleri
Alda Rubini
P. Soffitta

Works Cited by This (11)

Action Title Year Authors
+ PDF Chat Analyzing the data from X-ray polarimeters with Stokes parameters 2015 Fabian Kislat
Brian Clark
M. Beilicke
H. Krawczynski
+ PDF Chat A sealed Gas Pixel Detector for X-ray astronomy 2007 R. Bellazzini
G. Spandre
M. Minuti
L. Baldini
A. Brez
L. Latronico
N. Omodei
M. Razzano
M.M. Massai
M. Pesce-Rollins
+ PDF Chat Direct reading of charge multipliers with a self-triggering CMOS analog chip with 105k pixels at 50Îźm pitch 2006 R. Bellazzini
G. Spandre
M. Minuti
L. Baldini
A. Brez
Filippo Cavalca
L. Latronico
N. Omodei
Marco Maria Massai
C. Sgrò
+ PDF Chat Calibration of the IXPE instrument 2018 Carlo Lefevre
Raffaele Piazzolla
Alfredo Morbidini
Fabrizio Amici
Primo AttinĂ 
Mauro Centrone
E. Del Monte
Sergio Di Cosimo
Giuseppe Di Persio
Y. Evangelista
+ PDF Chat In-flight calibration system of imaging x-ray polarimetry explorer 2020 Riccardo Ferrazzoli
Fabio Muleri
Carlo Lefevre
Alfredo Morbidini
Fabrizio Amici
Daniele Brienza
E. Costa
E. Del Monte
Alessandro Di Marco
Giuseppe Di Persio
+ Design, construction, and test of the Gas Pixel Detectors for the IXPE mission 2021 L. Baldini
M. Barbanera
R. Bellazzini
R. Bonino
Fabio Borotto
A. Brez
Ciro Caporale
Claudia Cardelli
Simone Castellano
M. Ceccanti
+ The IXPE instrument calibration equipment 2021 Fabio Muleri
Raffaele Piazzolla
Alessandro Di Marco
Sergio Fabiani
Fabio La Monaca
Carlo Lefevre
Alfredo Morbidini
John Rankin
P. Soffitta
Antonino Tobia
+ The Instrument of the Imaging X-Ray Polarimetry Explorer 2021 P. Soffitta
L. Baldini
R. Bellazzini
E. Costa
L. Latronico
Fabio Muleri
E. Del Monte
Sergio Fabiani
M. Minuti
Michele Pinchera
+ An Algorithm to Calibrate and Correct the Response to Unpolarized Radiation of the X-Ray Polarimeter Onboard IXPE 2022 John Rankin
Fabio Muleri
Allyn F. Tennant
Matteo Bachetti
E. Costa
Alessandro Di Marco
Sergio Fabiani
Fabio La Monaca
P. Soffitta
Antonino Tobia
+ A Weighted Analysis to Improve the X-Ray Polarization Sensitivity of the Imaging X-ray Polarimetry Explorer 2022 Alessandro Di Marco
E. Costa
Fabio Muleri
P. Soffitta
Sergio Fabiani
Fabio La Monaca
John Rankin
Fei Xie
Matteo Bachetti
L. Baldini