WE-E-201B-01: GPU-Based Fast Cone Beam CT Reconstruction from Undersampled and Noisy Projection Data Via Total Variation

Type: Article

Publication Date: 2010-06-01

Citations: 3

DOI: https://doi.org/10.1118/1.3469447

Abstract

Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who are essentially excluded from receiving IGRT for this reason. The goal of this work is to develop a fast GPU-based algorithm to reconstruct CBCT from undersampled and noisy projection data so as to lower the imaging dose. Methods: The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. We developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multi-grid technique is also employed. Results: It is found that 20~40 x-ray projections are sufficient to reconstruct images with satisfactory quality for IGRT. The reconstruction time ranges from 77 to 130 sec on a NVIDIA Tesla C1060 GPU card, depending on the number of projections used, which is estimated about 100 times faster than similar iterative reconstruction approaches. Moreover, phantom studies indicate that our algorithm enables the CBCT to be reconstructed under a scanning protocol with as low as 0.1 mAs/projection. Comparing with currently widely used full-fan head and neck scanning protocol of ~360 projections with 0.4 mAs/projection, it is estimated that an overall 36~72 times dose reduction has been achieved in our fast CBCT reconstruction algorithm. Conclusions: This work indicates that the developed GPU-based CBCT reconstruction algorithm is capable of lowering imaging dose considerably. The high computation efficiency in this algorithm makes the iterative CBCT reconstruction approach applicable in real clinical environments.

Locations

  • arXiv (Cornell University) - View - PDF
  • DataCite API - View
  • Medical Physics - View

Similar Works

Action Title Year Authors
+ PDF Chat GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation 2010 Xun Jia
Yifei Lou
Ruijiang Li
William Y. Song
Steve Jiang
+ GPU-based Fast Low-dose Cone Beam CT Reconstruction via Total Variation 2010 Xun Jia
Yifei Lou
John H. Lewis
Ruijiang Li
Xuejun Gu
Chunhua Men
William Y. Song
Steve Jiang
+ GPU-based Cone Beam CT Reconstruction via Total Variation Regularization 2010 Xun Jia
Yifei Lou
John H. Lewis
Ruijiang Li
Xuejun Gu
Chunhua Men
Steve Jiang
+ PDF Chat GPU-based fast low-dose cone beam CT reconstruction via total variation 2011 Xun Jia
Yifei Lou
John H. Lewis
Ruijiang Li
Xuejun Gu
Chunhua Men
William Y. Song
Steve Jiang
+ PDF Chat GPU-based iterative cone-beam CT reconstruction using tight frame regularization 2011 Xun Jia
Bin Dong
Yifei Lou
Steve Jiang
+ PDF Chat GPU-based Fast Low Dose Cone Beam CT Reconstruction via Total Variation 2010 Xun Jia
Yifei Lou
R. Li
John H. Lewis
C Men
Xuejun Gu
W. Y. Song
S Jiang
+ PDF Chat A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections 2012 Xun Jia
Hao Yan
Laura Cerviño
Michael Folkerts
Steve Jiang
+ PDF Chat Fast Monte Carlo simulation for patient-specific CT/CBCT imaging dose calculation 2012 Xun Jia
Hao Yan
Xuejun Gu
Steve Jiang
+ Fast Scatter Artifacts Correction for Cone-Beam CT without System Modification and Repeat Scan 2015 Wei Zhao
Jun Zhu
Luyao Wang
+ PDF Chat Four‐dimensional cone beam CT reconstruction and enhancement using a temporal nonlocal means method 2012 Xun Jia
Zhen Tian
Yifei Lou
Jan‐Jakob Sonke
Steve Jiang
+ PDF Chat Spatiotemporal Gaussian Optimization for 4D Cone Beam CT Reconstruction from Sparse Projections. 2025 Yabo Fu
Hao Zhang
Weixing Cai
Huiqiao Xie
Licheng Kuo
Laura Cerviño
Jean M. Moran
Xiang Li
Tianfang Li
+ 2D antiscatter grid and scatter sampling based CBCT pipeline for image guided radiation therapy 2023 Farhang Bayat
Dan Ruan
Moyed Miften
Cem Altunbas
+ PDF Chat Comprehensive evaluations of cone-beam CT dose in image-guided radiation therapy via GPU-based Monte Carlo simulations 2014 Davide Montanari
E.G. Scolari
Chiara Silvestri
Yan Jiang Graves
Hao Yan
Laura Cerviño
R Rice
Steve Jiang
Xun Jia
+ 2D antiscatter grid and scatter sampling based CBCT pipeline for image guided radiation therapy. 2023 Farhang Bayat
Dan Ruan
Moyed Miften
Cem Altunbas
+ PDF Chat Artifact Reduction in 3D and 4D Cone-Beam Computed Tomography Images With Deep Learning: A Review 2024 Mohammadreza Amirian
Daniel Barco
Ivo Herzig
F.-P. Schilling
+ Iterative Algorithms for Volumetric X-ray Computed Tomography 2012 Wei Qiu
+ PDF Chat A model‐based scatter artifacts correction for cone beam CT 2016 Wei Zhao
Don Vernekohl
Jun Zhu
Luyao Wang
Lei Xing
+ PDF Chat WE-E-213CD-04: CT to Cone-Beam CT Deformable Registration With Simultaneous Intensity Correction 2012 Xin Zhen
Hui Yan
Xuejun Gu
L Zhou
Xun Jia
Steve Jiang
+ End-to-end Memory-Efficient Reconstruction for Cone Beam CT 2022 Nikita Moriakov
Jan‐Jakob Sonke
Jonas Teuwen
+ Motion Artifacts Detection in Short-scan Dental CBCT Reconstructions 2023 Abdul Salam Rasmi Asraf Ali
Andrea Fusiello
Claudio Landi
Cristina Sarti
Anneke Annassia Putri Siswadi